Set Diode Current (%)
The set value must be less than 100% and above
the minimum current setting value, which can be
set to 0. If the set value is greater than 100, the
default is input 100.
Send: ‘SDC 100\r’
Return: ‘SDC:100\r’
Other return values:
‘ERR: Input Err\r’
‘Laser is worked in AD Mode\r’
Send: ‘RCS\r’
Return: ‘RCS: 56.7\r’
(The current set value is 56.7 %)
Read Pulse Repetition Rate (Hz)
Send: ‘RPRR\r’
Return: ‘RPRR:10\r’
(Repeat frequency is10Hz)
Send: ‘RBT\r’
Return: ‘RBT:36.6\r’
Send: ‘RPW\r’
Return: ‘RPW:5.5\r’
(pulse width is 5.5ms)
Send: ‘RCT\r’
Return: ‘RCT:34.5\r’
Send: ‘PERR\r’
Return: ‘PERR\r’
Send: ‘SUT 50\r’
Return: ‘SUT:50\r’
Send: ‘SDT 50\r’
Return: ‘SDT:50\r’
Send: ‘RUT \r’
Return: ‘RUT:50\r’
Send: ‘RDT \r’
Return: ‘RDT:50\r’
Send: ‘PSRT 1\r’
Return: ‘PSRT:1\r’
Send: ‘PSTP\r’
Return: ‘PSTP\r’
Enable Calibration Mode
–Power linear correction mode (in this mode, the
external analog is corrected and output after
filtering, so the response time of AD analog is
larger than that of through mode)
Send: ‘ECM \r’
Return: ‘ECM\r’