44
DCM
Disable Calibration Mode
(AD analog response time is less than 100 us in
this mode)
Send: ‘DCM\r’
Return: ‘DCM\r’
Others
Command Error
Send: ‘BGM\r’
Return: ‘Command Err!\r’
STA
Read Device Status
– Read the product status. A return value of 32-Bit
digital information. The meaning of each Bit is as
follows (undefined or ‘reserved’ Bit negligible):
Send: ‘STA’
Return: ‘STA:4100’
returned value 4100(Decimal) can be
converted to 0 x1004 (hexadecimal), and
then converted to binary to see that Bits2
and 12 have been set. The laser enable is
on and the modulation mode is enabled.
Bit 0
Normal operation
Authorization time
Bit 1
Normal
Temperature too high
Bit 2
Emission off
Emission on or in preparation
Bit 3
No high reflection
High reflection Abnormal
Bit 4
External AD mode=off
External AD mode=on
Bit 5
Power Correction Mode=off
Power Correction Mode=on
Bit 6
Normal
Sub-controlling communication
abnormal
Bit 7
Normal
Sub-module abnormal
Bit 8
Guide red light=off
Guide red light=on
Bit 9
The laser is not ready
The laser is ready
Bit 10
QCW mode=off
QCW mode=on
Bit 11
Module Main Power=off
Module Main Power=on
Bit 12
Modulation mode=off

Table of Contents