Circuit Board Alarms—Controller Functions
B-2 SmartEdge 100 Router Hardware Guide
Circuit Board Alarms—Controller Functions
Table B-2 lists the supported alarms for the controller functions on the circuit board.
Circuit Board Alarms—I/O Carrier Card Functions
Table B-3 lists the supported alarms for the I/O carrier card functions on the circuit board.
Table B-2 Alarms for the Controller Functions on the Circuit Board
Description Severity Probable Cause Service Affecting
Controller code mismatch Major ReplaceableUnitTypeMismatch Yes
Controller fail Critical ReplaceableUnitProblem Yes
Controller overheating Major ReplaceableUnitProblem Yes
Controller power-on diagnostic failed Major ReplaceableUnitProblem Yes
Controller temperature critical Major ReplaceableUnitProblem Yes
Diagnostic test fail Major ReplaceableUnitProblem Yes
Local inventory fail Major ReplaceableUnitProblem Yes
Nonvolatile memory fail Major CorruptData Yes
Real-time clock failure Major RealTimeClockFailure Yes
Table B-3 Alarms for the I/O Carrier Card Functions on the Circuit Board
Description Severity Probable Cause Service Affecting
Circuit pack card code mismatch Minor ReplaceableUnitTypeMismatch No
Circuit pack failure Critical ReplaceableUnitProblem Yes
Circuit pack mismatch Critical ReplaceableUnitTypeMismatch Yes
Circuit pack missing Critical ReplaceableUnitMissing Yes
Circuit pack overheating Major LineCardProblem Yes
Circuit pack power-on diagnostic failed Major ReplaceableUnitProblem Yes
Circuit pack reset completed Warning OperationNotification Yes
Diagnostic fail Major ReplaceableUnitProblem Yes
Software download completed Warning OperationNotification Yes
Software download failed Warning OperationFailure Yes
Synchronization failure Critical TimingProblem Yes
Voltage failure detected Major ReplaceableUnitProblem Yes