Planning the Site and Installation
3-4 SmartEdge 100 Router Hardware Guide
Environmental Requirements
The installation area for the SmartEdge 100 hardware must allow a minimum of 20.0 inches (50.8 cm) at
the front of the chassis (for maintenance and ventilation).
Because the cooling air exits at the rear of the chassis, this area must not be blocked; nor must exhaust air
from other equipment blow into the front of the SmartEdge 100 chassis.
Table 3-6 lists the environmental requirements for the installation site of the SmartEdge 100 hardware.
Physical Specifications
Table 3-7 lists the SmartEdge 100 physical specifications.
Caution Risk of equipment damage. Lack of proper cooling and ventilation can damage a SmartEdge
router. To reduce the risk, never install the chassis in an unventilated area, and always ensure
that cooling equipment sufficient to maintain a temperature of less than 104°F (40°C) is
available.
Table 3-6 Environmental Requirements
Specification Value
GR-3028-CORE equipment class (S) F-SR
Cooling Forced air (fan cooled)
Operating temperature, short term
1
1. Short term refers to a period of time not more than 96 consecutive hours and a total of not more than
15 days in one year (360 hours in any given year, but no more than 15 occurrences during that year).
23° to 131°F (–5° to 55°C)
Operating temperature, long term
2
2. Long term refers to normal operating conditions.
41° to 104°F (5° to 40°C)
Storage temperature –40° to 158°F (–40° to 70°C)
Operating humidity 10 to 90% (noncondensing)
Operating altitude 0 to 10,000 ft (3,048m)
Earthquake Telcordia 63-CORE Zone 4-compliant
Thermal dissipation, nominal
Thermal dissipation, maximum
205 watts (700 BTU/hour)
300 watts (1023 BTU/hour)
Table 3-7 SmartEdge 100 Physical Specifications
Mechanical Specification Value
Chassis dimensions 3.5 inches (8.9 cm) height
17.5 inches (44.5 cm) width
19.6 inches (50.0 cm) depth
Chassis weight 20.0 lb (9.1 kg) all MIC slots filled, ready for installation
Chassis mounting 19- or 23-inch rack
Slots 2
MIC slots 2 (circuit board slot 2)