Managing Hardware with CLI Commands
5-10 SmartEdge 100 Router Hardware Guide
Values for CLI Input Arguments
Table 5-8 lists the values for the input arguments in the CLI commands. Values for input arguments that are
shown in bold must be entered in the specified format.
Values for CLI Output Fields
Table 5-9 describes the output fields for the show chassis command (in any mode).
Table 5-8 Values for CLI Input Arguments
Argument Range of Values/Description Restrictions
port 1 to 26. The Ethernet management port is always port 1 in
slot 1.
Native ports are always ports 1 and 2 in slot 2.
MIC ports range from 3 to 14 in the left MIC slot
and 15 to 26 in the right MIC slot. For each type of
MIC, see Table 5-12 on page 5-13 for the range of
ports.
port-type ethernet—FE or GE port (any version).
slot 1—Slot in which the Ethernet management port is configured.
2—Slot for all native and MIC ports.
Note The following notes apply to the flags displayed by the show chassis command:
The SmartEdge 100 router does not display the following flags: B, C, G, M, N, S, U, W, and X.
D—The default traffic card processes packets sent to it from the controller. For a description of
the functions of the default traffic card, see the “Card, Port, and Channel Operations” chapter in
the Ports, Circuits, and Tunnels Operations Guide for the SmartEdge OS.
H—The I/O carrier card is administratively shut down with the shutdown command (in card
configuration mode).
O—The I/O carrier card is placed in the ODD state with the on-demand diagnostic command
(in card configuration mode).
The I/O carrier card is ready (R flag) when the it has been initialized and the code for the PPAs
has been downloaded; it is up (U flag) when the PPAs on the I/O carrier card are registered with
the requisite NetBSD process.
Table 5-9 Output Fields for the show chassis Command
Field Description
Current platform is Chassis type—SE100—SmartEdge 100 router.
Slot slot—Slot number for this unit.
Configured type Slot is configured for:
carrier—I/O carrier card functions on the circuit board; always reported for slot 2.
xcrp—Controller functions on the circuit board; always reported for slot 1.
Installed type Slot always has a card installed:
carrier—Traffic card functions on the circuit board; always reported for slot 2.
xcrp—Controller functions on the circuit board; always reported for slot 1.