Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98
65
17 Preprogrammed EEPROM
17.1 Factory-Programmed Options
The EEPROM (Electrically Erasable Programmable Read Only Memory) contains information that is used
by the microprocessors. This information determines what options the system will perform.
The 4720 is shipped with an EEPROM that has been factory-programmed with the options listed below so
that the system is operational as soon as it is installed. Any options not listed below have default values of
“NO” or “Zero” or “Blank.”
For more information on these options, see the Model 4720 Programming Options Descriptions (P/N
150299).
17.1.1 System Options:
Default Mode = FORCE CLOSE (See note under BATTERY in Section 23.);
Dialer = YES;
E/E Beep PZT = YES;
Swinger Bypass = YES;
Delayed Bypass = YES;
Max SKEY ID = 1;
Disp Speed = 1.5 seconds
17.1.2 Internal Zones:
Zone Mode = STANDARD;
Last Internal Z# = 16;
Zone 1 (Fire) = N.O., 24-Hour Alarm, 24-Hour Supervised, Not Bypassable;
Zones 2-16 (Intrusion) = N.O., Bypassable;
all Zone Speeds = 2 (62 MS).
17.1.3 Expansion Zones:
Last Exp1 Z# = 80;
Last Exp2 Z# = 80;
Residence Code = 0123;
Zones 17-80 (Intrusion) = Bypassable.
17.1.4 Dialer:
Answer Ring = YES;
Up/Down Used = YES;
Fail Attempt = 5;
Total Attempts = 10;
# Rings = 10;
AC Loss Hours = 4;
Report Alarm to ph1;
Report Trouble to ph1;
Report Op Reset to ph1;
Report Test to ph1;
Report Trouble to ph1;
Must Report to ph1;
Format 1-4 = SIA8;
Attempts 1-4 = 1.