63
Alarms
The following alarms may be generated when this cycle is executed.
BROKEN TOOL
FORMAT ERROR
RPM OUT OF RANGE
For an explanation of the meaning of alarms, see “Error messages
and alarms” on page 85.
Example
Broken tool detection – plunge check
%_N_????
T1
M6
D1
G0Z200. Move to a safe position where the broken tool
cycle can be called.
X200.Y300.
L9800
R26=100. Make a broken tool check. Either a broken
L9863 tool alarm is raised and the program stops, or
the program continues.
T2 Select the next tool and continue.
M6
(continue machining)
Broken tool detection (plunge check)