10.42 Configuration – History
This page determines if measurements are logged into the ASM’s data memory and the period at which these values are
logged.
Recover “Last Recorded” Status values after power loss:
This Enables or Disables whether “last recorded values” are restored after a power outage, or whether values remain at their
power on defaults until a valid measurement is made for each field.
Rx Power Logging:
This setting Enables or Disables the Rx power level logging. Disabling the logging at any time will not affect any data already
captured.
Tx Power Logging:
This setting Enables or Disables the Tx power level logging. Disabling the logging at any time will not affect any data already
captured.
VSWR Level Logging:
This setting Enables or Disables the VSWR power level logging. Disabling the logging at any time will not affect any data
already captured.
Alarm Module Input Level Logging:
This setting Enables or Disables the Alarm Module input level logging. Disabling the logging at any time will not affect any data
already captured.
Logging Interval:
This sets the interval between the logging snapshots. For example, if set to “10 sec”, a snapshot of all the current levels is
taken and saved every 10 seconds.