SC532 D
Left fusing pressure motor home position error 1
The left pressure motor did not arrive at the home position within 23 sec. after the left
pressure motor started.
Left fusing pressure motor home position sensor loose, broken, defective.
Sensor defective.
Motor drive mechanism overloaded
Motor defective.
SC533 D
Left fusing pressure motor home position error 2
The left pressure motor remained at the home position for 3 sec. after the motor
switched on.
Left fusing pressure motor home position sensor loose, broken, defective.
Left fusing pressure motor drive mechanism overloaded
Sensor defective.
Motor defective.
SC534 D
Right fusing pressure motor home position error 1
The right pressure motor did not arrive at the home position 23 sec. after the right
pressure motor switched on.
Right fusing pressure motor home position sensor loose, broken, defective.
Right fusing pressure motor drive mechanism overloaded
Sensor defective.
Motor defective.
SC535 D
Right fusing pressure motor home position error 2
The right pressure motor remained at the home position 3 sec. after motor switched
on.
Right fusing pressure motor home position sensor loose, broken, defective.
Right fusing pressure motor drive mechanism overloaded
Sensor defective.
Motor defective.