[0 or 1/ 0 / - ]
0: Disable. Setting the fax unit off-hook does not interrupt a fax transaction in progress. If
the off-hook button is pushed during a embedded RCG-M transmission, the button must be
pushed again to set the fax unit on-hook after the embedded RCG-M transmission has
completed.
1: Enable. When embedded RCG-M shares a line with a fax unit, setting the fax unit off-
hook will interrupt a embedded RCG-M transmission in progress and open the line for a fax
transaction.
200
Manual Polling
No information is available at this time.
201
Regist: Status
Displays a number that indicates the status of the @Remote service device.
0 Neither the registered device by the external nor embedded RCG device is set.
1
The embedded RCG device is being set. Only Box registration is completed. In this
status, this unit cannot answer a polling request from the external RCG.
2
The embedded RCG device is set. In this status, the external RCG unit cannot answer
a polling request.
3
The registered device by the external RCG is being set. In this status the embedded
RCG device cannot be set.
4 The registered module by the external RCG has not started.
202
Letter Number
Allows entry of the number of the request needed for the embedded RCG.
203
Confirm Execute
Executes the inquiry request to the @Remote Gate Way URL.
204
Confirm Result
Displays a number that indicates the result of the inquiry executed with SP5816-203.
0 Succeeded
1 Inquiry number error
2 Registration in progress
System Service Mode
173
8