The actual amount of time is this setting + 2 sec. For example, if you set "2", the line will
remain open for 4 sec.
163
Access Point
This is the telephone number of the dial-up access point for embedded RCG-M. If no setting
is done for this SP code, then a preset value (determined by the country selected) is used.
Default: 0
Allowed: Up to 16 numeral characters
164
Line Connecting
This SP sets the connection conditions for the customer. This setting dedicates the line to
embedded RCG-M only, or sets the line for sharing between embedded RCG-M and a fax
unit.
[0 or 1 / 0 / - ]
0: Line shared by embedded RCG-M/Fax
1: Line dedicated to embedded RCG-M only
• If this setting is changed, the copier must be cycled off and on.
• SP5816-187 determines whether the off-hook button can be used to interrupt an
embedded RCG-M transmission in progress to open the line for fax transaction.
173
Modem serial No.
This SP displays the serial number registered for the embedded RCG-M.
174
Retransmission Limit
Normally, it is best to allow unlimited time for certification and ID2 update requests, and for
the notification that the certification has been completed. However, embedded RCGM
generates charges based on transmission time for the customer, so a limit is placed upon the
time allowed for these transactions.
If these transactions cannot be completed within the allowed time, do this SP to cancel the
time restriction.
186
RCG - C M Debug Bit SW DFU
This is a debugging tool used by Designers.
187
FAX TX Priority
This SP determines whether pushing the off-hook button will interrupt an embedded RCGM
transmission in progress to open the line for fax transaction. This SP can be used only if
SP5816-164 is set to "0".
8. Appendix: SP Mode Tables
172