SERVICE RAM ADDRESSES 30 November, 1999
4-50
8000A2(H) - User parameter switch 02
Bit 0: Forwarding mark printing on forwarded messages 0: Disabled, 1: Enabled
Bit 1: Center mark printing on received copies 0: Disabled, 1: Enabled
Bit 2: Not used
Bit 3: TSI included in transmitted messages 0: Disabled, 1: Enabled
Bits 4 to 7: Not used
8000A3(H) - User parameter switch 03
(Automatic report printout)
Bit 0: Transmission result report (memory transmissions) 0: Off, 1: On
Bit 1: Not used
Bit 2: Memory storage report 0: Off, 1: On
Bit 3: Not used
Bit 4: Polling result report (polling reception) 0: Off, 1: On
Bit 5: Transmission result report (immediate transmissions) 0: Off, 1: On
Bit 6: Not used
Bit 7: Journal 0: Off, 1: On
8000A4(H) - User parameter switch 04
Bit 0: Confidential reception report 0: Off, 1: On
Bits 1 to 6: Not used
Bit 7: Includes a sample image on reports 0: Off, 1: On
8000A5(H) - User parameter switch 05
Bit 0: Substitute reception 0: Off, 1: On
Bit 1: Memory reception if no RTI or CSI received 0: Possible, 1: Impossible
Bits 2 to 5: Not used
Bit 6: Fusing lamp control during energy saver mode
0: Lamp off, 1: Standby temperature
Bit 7: Not used (keep this bit at 0.)
8000A6(H) - User parameter switch 06
Bit 0: TTI 0: Off, 1: On
Bits 1 to 3: Not used
Bit 4: Batch transmission 0: Off, 1: On
Bits 5 to 7: Not used
8000A7(H) - User parameter switch 07
Not used