30 November, 1999 BIT SWITCHES
4-15
Service
Tables
How to calculate the RX level listed on the Journal (when bit 2 of system switch 00
is set to 1)
Example:
32 V34 288
L 01 00
00 00
The four-digit hexadecimal value (N) after L indicates the RX level.
The high byte is given first, followed by the low byte. Divide the decimal value of N
by -16 to get the RX level.
In this above example, the decimal value of N (=0100[H]) is 256.
So, the actual RX level is 256/-16 = -16 dB.
Communication Parameters
Mode DCS: ITU-T standard NSS: Non-standard G3
Modem rate
336: 33600 BPS 168: 16800 BPS
312: 31200 BPS 144: 14400 BPS
288: 28800 BPS 120: 12000 BPS
264: 26400 BPS 96: 9600 BPS
240: 24000 BPS 72: 7200 BPS
216: 21600 BPS 48: 4800 BPS
192: 19200 BPS 24: 2400 BPS
Communication mode ECM: With ECM SSC: Using SSC
NML: With no ECM, SSC
Compression mode
MMR: MMR compression
MR: MR compression
MH: MH compression
Resolution
F: Fine, transmitted at 8 x 15.4 dots per mm
D: Detail, transmitted at 8 x 7.7 dots per mm
S: Standard, transmitted at 8 x 3.85 dots per mm
I/O rate 0: 0 ms/line 10: 10 ms/line
25: 2.5 ms/line 20: 20 ms/line
5: 5 ms/line 40: 40 ms/line
ā€40ā€ is displayed while receiving a fax message using AI
short protocol.
Width and reduction A4: A4 (8.3"), no reduction
B4: B4 (10.1") no reduction
System Switch 01
No FUNCTION COMMENTS
0 PM call
0: Disabled 1: Enabled
This bit switch determines whether the machine
will send an Auto Service Call to the service
station when it is time for PM.
1-7
Not used Do not change these settings.