BIT SWITCHES 30 November, 1999
4-16
System Switch 02
No FUNCTION COMMENTS
0 Memory file transfer
0: Disabled
1: Enabled
1: All messages in the memory (including
confidential RX messages) are sent to the fax
number, which is programmed as the service
station.
Always reset this bit to zero after transfer.
Cross-reference
Service station number programming: Function
13
1-2
Not used Do not change these settings.
3
Substitute reception file
printout
0: Full size only
1: Reduce to the paper size
1: If the paper in the cassette is smaller than the
received message, the machine reduces the
incoming message to the paper size before
printing.
4-5
Not used Do not change these settings.
6
7
Memory read/write by RDS
Bit 7 6 Setting
0 0 Always disabled
0 1 User selectable
1 0 User selectable
1 1 Always enabled
(0,0): All RDS systems are always locked out.
(0,1), (1,0): At any time, an RDS system can
access the machine.
(1,1): At any time, an RDS system can access
the machine.
System Switch 03
No FUNCTION COMMENTS
0
to
7
Length of time that RDS is
temporarily switched on when
bits 6 and 7 of System Switch
02 are set to "User selectable"
00 - 99 hours (BCD).
This data is only valid if bits 6 and 7 of System
Switch 02 are set to "User selectable".
The default setting is 24 hours.
System Switch 04
No FUNCTION COMMENTS
0-2
Not used Do not change these settings.
3
Dedicated transmission
parameter programming
0: Disabled 1: Enabled
Set this bit to 1 before changing any dedicated
transmission parameters.
4
Inclusion of the Start key in
Keystroke Programs
0: Not needed 1: Needed
0: The user does not need to press the Start key
when operating a keystroke program.
5
Not used Do not change the settings.
6
CSI programming level
0: User level 1: Service level
1: Only a service function can program the CSI.
7
Telephone line type
programming mode
0: User level 1: Service level
1: Only a service function can program the
telephone line type selection.