Setting Item Max. Value Min. Value Step Unit
10: Level: BW/FC/FCS 16 1 1 None
FCS: Fuser Setting HQ
Under conditions below, set range of fusing start temperature.
FC with S HQ is applied in DFE Setting
The lager value becomes, the earlier printing starts. However, fusing quality may become lower.
Setting Item Max. Value Min. Value Step Unit
11: Level: Clear/Special/12: Level:
White/13: Level: Metallic/14: Level:
Option
16 1 1 None
S: Fuser Setting HQ
Under conditions below, set range of fusing start temperature.
Print using S Only
HQ is applied in DFE
The lager value becomes, the earlier print starts. However, fusing quality may become lower.
Setting Item Max. Value Min. Value Step Unit
15: Level: Clear/Special/16: Level:
White/17: Level: Metallic/18: Level:
Option
16 1 1 None
1236: Fusing Pressure Roller Cooling
BW/FC/FCS
Under the following conditions, set the cooling fan level of pressure roller.
Black & White/Full Color/Full Color including Special Color
High Quality is not applied in DFE Setting
12: Machine: Image Quality
181