2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
:MEASure:F2RDeLay:SMAXimum?
:MEASure:F2RDeLay:SMINimum?
:MEASure:F2RDeLay:SCURrent?
:MEASure:F2RDeLay:SAVerage?
:MEASure:F2RDeLay:SDEViation?
Syntax 1
:MEASure:F2RDeLay:SMAXimum <chanA>,<chanB>
:MEASure:F2RDeLay:SMINimum <chanA>,<chanB>
:MEASure:F2RDeLay:SCURrent <chanA>,<chanB>
:MEASure:F2RDeLay:SAVerage <chanA>,<chanB>
:MEASure:F2RDeLay:SDEViation <chanA>,<chanB>
Description 1
Enable the delay measurement function (falling edge-rising edge) between the two specified channels
and enable the statistic function.
Syntax 2
:MEASure:F2RDeLay:SMAXimum? <chanA>,<chanB>
:MEASure:F2RDeLay:SMINimum? <chanA>,<chanB>
:MEASure:F2RDeLay:SCURrent? <chanA>,<chanB>
:MEASure:F2RDeLay:SAVerage? <chanA>,<chanB>
:MEASure:F2RDeLay:SDEViation? <chanA>,<chanB>
Description 2
Enable the delay measurement function (falling edge-falling edge) between the two specified channels;
enable the statistic function; return the maximum value and minimum value, current value, average value
or standard deviation.
Parameter
Name Type Range Default
<chanA> Discrete
{D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D11|
D12|D13|D14|D15|CHANnel1|CHANnel2}
--
<chanB> Discrete
When <chanA> is D0-D15:
{D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D11|D12|D13|D14|
D15}
When <chanA> is CHANnel1 or CHANnel2:
{CHANnel1|CHANnel2}
--
Return Format
The query returns the measurement result in scientific notation.