EasyManuals Logo

Rigol 2000 Series Programming Guide

Rigol 2000 Series
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-15
:BUS<n> Commands
:BUS<n>:MODE
:BUS<n>:DISPlay
:BUS<n>:FORMat
:BUS<n>:EVENt
:BUS<n>:EEXPort
:BUS<n>:DATA?
:BUS<n>:PARallel
:BUS<n>:RS232 (Option)
:BUS<n>:IIC (Option)
:BUS<n>:SPI (Option)
:BUS<n>:MODE
Syntax
:BUS<n>:MODE <mode>
:BUS<n>:MODE?
Description
Set or query the decoding mode of the specified bus.
Parameter
Name Type Range Default
<n> Discrete {1|2} --
<mode> Discrete {PARallel|RS232|IIC|SPI|CAN} PARallel
Explanation
RS232 decoding, I2C decoding, SPI decoding and CAN decoding are options and this command is only
valid when the corresponding options are installed.
Return Format
The query returns PAR, RS232, IIC, SPI or CAN.

Table of Contents

Other manuals for Rigol 2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol 2000 Series and is the answer not in the manual?

Rigol 2000 Series Specifications

General IconGeneral
BrandRigol
Model2000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals