EasyManuals Logo

Rigol 2000 Series Programming Guide

Rigol 2000 Series
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #250 background imageLoading...
Page #250 background image
RIGOL 2 Command System
2-234 MSO2000A/DS2000A Programming Guide
[:SOURce<n>]:MOD:FM[:DEVIation]
Syntax
[:SOURce<n>]:MOD:FM[:DEVIation] {<dev>|MINimum|MAXimum}
[:SOURce<n>]:MOD:FM[:DEVIation]? [MINimum|MAXimum]
Description
Set or query the frequency deviation of FM . The default unit is Hz.
Parameter
Name Type Range Default
<dev> Real
0Hz to the current frequency of the carrier
waveform. The sum of the frequency
deviation and carrier frequency cannot be
greater than the sum of the upper limit of the
carrier frequency and 1kHz.
1kHz
<n> Discrete {1|2} 1
Return Format
The query returns the current frequency deviation in scientific notation.
[:SOURce<n>]:MOD:FM:INTernal:FREQuency
Syntax
[:SOURce<n>]:MOD:FM:INTernal:FREQuency {<frequency>|MINimum|MAXimum}
[:SOURce<n>]:MOD:FM:INTernal:FREQuency? [MINimum|MAXimum]
Description
Set or query the modulating waveform frequency of FM. The default unit is Hz.
Parameter
Name Type Range Default
<frequency> Real 1Hz to 50kHz 1kHz
<n> Discrete {1|2} 1
Return Format
The query returns the current modulating waveform frequency in scientific notation.

Table of Contents

Other manuals for Rigol 2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol 2000 Series and is the answer not in the manual?

Rigol 2000 Series Specifications

General IconGeneral
BrandRigol
Model2000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals