RIGOL 2 Command System
2-200 MSO2000A/DS2000A Programming Guide
:MEASure:MARea
Syntax 1
:MEASure:MARea <chan>
Description 1
Enable the area measurement function of the specified channel.
Syntax 2
:MEASure:MARea? <chan>
Description 2
Enable the area measurement function of the specified channel and return the measurement result (the
unit is Vs)
Parameter
Name Type Range Default
<chan> Discrete {CHANnel1|CHANnel2|MATH} --
Return Format
The query returns the measurement result in scientific notation.
Example
:MEASure:MARea CHANnel1
:MEASure:MARea? CHANnel1
You can use the following commands to query the statistic maximum, minimum, current value, average
and standard deviation of the area measurement values of the specified channel waveform. Sending the
following commands will enable the statistic function automatically.
:MEASure:MARea:SMAXimum?
:MEASure:MARea:SMINimum?
:MEASure:MARea:SCURrent?
:MEASure:MARea:SAVerage?
:MEASure:MARea:SDEViation?