2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-233
[:SOURce<n>]:MOD:AM:INTernal:FREQuency
Syntax
[:SOURce<n>]:MOD:AM:INTernal:FREQuency {<frequency>|MINimum|MAXimum}
[:SOURce<n>]:MOD:AM:INTernal:FREQuency? [MINimum|MAXimum]
Description
Set or query the modulating waveform frequency of AM. The default unit is Hz.
Parameter
Name Type Range Default
<frequency> Real 1Hz to 50kHz 1kHz
<n> Discrete {1|2} 1
Return Format
The query returns the current modulating waveform frequency in scientific notation.
[:SOURce<n>]:MOD:AM:INTernal:FUNCtion
Syntax
[:SOURce<n>]:MOD:AM:INTernal:FUNCtion <wave>
[:SOURce<n>]:MOD:AM:INTernal:FUNCtion?
Description
Set or query the modulating waveform of AM.
Parameter
Name Type Range Default
<wave> Discrete {SINusoid|SQUare|RAMP|NOISe} SINusoid
<n> Discrete {1|2} 1
Return Format
The query returns SIN, SQU, RAMP or NOIS.