2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
:MEASure:NWIDth:SMAXimum?
:MEASure:NWIDth:SMINimum?
:MEASure:NWIDth:SCURrent?
:MEASure:NWIDth:SAVerage?
:MEASure:NWIDth:SDEViation?
Syntax 1
:MEASure:NWIDth:SMAXimum <chan>
:MEASure:NWIDth:SMINimum <chan>
:MEASure:NWIDth:SCURrent <chan>
:MEASure:NWIDth:SAVerage <chan>
:MEASure:NWIDth:SDEViation <chan>
Description 1
Enable the negative pulse width measurement function of the specified channel and enable the statistic
function.
Syntax 2
:MEASure:NWIDth:SMAXimum? <chan>
:MEASure:NWIDth:SMINimum? <chan>
:MEASure:NWIDth:SCURrent? <chan>
:MEASure:NWIDth:SAVerage? <chan>
:MEASure:NWIDth:SDEViation? <chan>
Description 2
Enable the negative pulse width measurement function of the specified channel; enable the statistic
function; return the maximum value, minimum value, current value, average value or standard deviation.
Parameter
Name Type Range Default
<chan> Discrete
{D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D11|
D12|D13|D14|D15|CHANnel1|CHANnel2|MATH}
--
Return Format
The query returns the measurement result in scientific notation.