EasyManuals Logo

Rigol 2000 Series Programming Guide

Rigol 2000 Series
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #327 background imageLoading...
Page #327 background image
2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-311
:TRIGger:SLOPe:WINDow
Syntax
:TRIGger:SLOPe:WINDow <window>
:TRIGger:SLOPe:WINDow?
Description
Set or query the vertical window type in slope trigger.
Parameter
Name Type Range Default
<window> Discrete {TA|TB|TAB} TA
Explanation
Different vertical windows correspond to different trigger level adjustment modes.
TA: only adjust the upper limit of the trigger level.
TB: only adjust the lower limit of the trigger level.
TAB: adjust the upper and lower limits of the trigger level at the same time.
Return Format
The query returns TA, TB or TAB.

Table of Contents

Other manuals for Rigol 2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol 2000 Series and is the answer not in the manual?

Rigol 2000 Series Specifications

General IconGeneral
BrandRigol
Model2000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals