2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-27
:BUS<n>:RS232:BUSer
Syntax
:BUS<n>:RS232:BUSer <baud>
:BUS<n>:RS232:BUSer?
Description
Set or query the user-defined baud rate of data transmission in RS232 decoding on the specified bus. The
default unit is bps.
Parameter
Name Type Range Default
<n> Discrete {1|2} --
<baud> Integer 50 to 20000000 9600
Return Format
The query returns the baud rate currently set in integer.
:BUS<n>:RS232:DBITs
Syntax
:BUS<n>:RS232:DBITs <bits>
:BUS<n>:RS232:DBITs?
Description
Set or query the data width of RS232 decoding on the specified bus.
Parameter
Name Type Range Default
<n> Discrete {1|2} --
<bits> Discrete {5|6|7|8|9} 8
Return Format
The query returns 5, 6, 7, 8 or 9.