RIGOL Chapter 6 Frequency Sweep Output
User’s Guide for DG5000
6-6
Step Sweep
The output frequency of the instrument is steppingfrom Start Frequencyto End
Frequency. The duration of the output signal on each frequency point is determined
by Sweep Timeand Step Number.
When Sweep is enabled, press SwpType to select Step. In Graphic Mode, a step
waveform, which indicates the output frequency is changing in stepmode, will
appear on the screen (shown in the figure below). Now, use
to open the 2/2
menu page, press StepNum and use the numeric keyboard or the knob to set the
step number. The default is 2 and the available range is from 2 to 2048. Notice that,
the StepNum menu is grayed out and disabled in Linearand Logsweep type
mode.