RIGOL Chapter 10 Advanced Operation
User’s Guide for DG5000
10-40
To Configure the Remote Interface
DG5000 is furnished with USB, GPIB (IEEE-488) and LAN interface and enables to
access the I/O configuration parameters using for remote control from GPIB or LAN
interface (USB parameters neednt to be configured).
Press Utility I/O Setup to open the interface setting menu and select GPIB or
LAN interface. The selection is stored in nonvolatile memory.
To Set GPIB Address
Each device on the GPIB (IEEE-488) interface must have a unique address.
Press Utility I/O Setup GPIB Address, and use the numeric keyboard or the
knob to set the GPIB address as a value within 0 and 30, the default value is “2”. The
selected address is stored in nonvolatile memory.
LAN Setting
Press Utility I/O Setup LAN to open the LAN parameters configuration
interface as shown in the following figure. You could examine the LAN status and
configure the LAN parameters.
Figure 10-4 LAN Setting Interface
Current IP Configure Mode
Network Status
IP Configure Mode status
MAC Address
VISA Descriptor
w ww. . com