RIGOL Chapter 2 Basic Waveform Output
User’s Guide for DG5000
2-2
To Output Sine Waveform
To output a sine waveform from CH1 with 20 kHz frequency, 2.5 Vpp amplitude, 500
mVDC offset and 10 ° start phase.
1. Select Channel
Press CH1|CH2 to select CH1. CH1in Channel Label Bar will be highlighted
indicating that CH1 has been selected.
2. Select Sine Waveform
Press Sine to select Sine waveform. The key will be illuminated and the
corresponding menus display at the bottom of the screen.
3. Set the Frequency/Period
Press Freq/Period to highlight Freq, and then use the numeric keyboard to
input “20” and select the unitkHzin the pop-up menu.
Sine waveform frequency range: 1 μHz to 350 MHz.
Press the softkey again to switch to Period.
Selectable frequency units: MHz, kHz, Hz, mHz, μHz.
Selectable period units: sec, msec, μsec, nsec.
You can also use the knob to modify this parameter.
4. Set the Amplitude
Press Ampl/HiLevel to highlight Ampl, and then use the numeric keyboard to
input “2.5” and select the unit Vppin the pop-up menu.
The amplitude range is limited by the Resistanceand Freq/Period
settings. Please refer to the “Output Characteristic” described in
Specifications.
Amplitude and offset, HiLevel and LoLevel, always exist in pairs. Press the
softkey again to switch to HiLevel.
Selectable amplitude units: Vpp, mVpp, Vrms, mVrms, dBm (non-high
impedance).
Selectable high level units: V, mV.
You can also use the knob to modify this parameter.
5. Set the DC Voltage Offset
Press Offset/LoLevel to highlight Offset, and then use the numeric keyboard
w ww. . com