5 Troubleshooting
Rittal Perforex BC machining centre 33
EN
5 Troubleshooting
Fault message /
malfunction
Cause
Remedy
The controller can no
longer be switched on
No compressed air
Establish compressed
air supply
Insufficient pressure
(< 5.5 bar)
Check the pressure, in-
crease if necessary
EMERGENCY STOP
pressed
Trigger EMERGENCY
STOP
Other safety equipment
triggered
Switch off the controller
and restart
Program does not start /
the controller can no
longer be switched on
X, Y or Z axis at the limit
position
Move the appropriate
axis in manual operation
from the limit position
Closed-loop controllers
not ready
Safety area is not free
Make safety area free
Entered traversal path
too large
Correction of the soft-
ware limit position
No pressure! Only restart
possible
No compressed air
Establish compressed
air supply
Insufficient pressure
(< 5.5 bar)
Check the pressure, in-
crease if necessary
: Faults