7 Technical specifications
Rittal Perforex BC machining centre 39
EN
7 Technical specifications
The exact technical specifications depend on your selected machine config-
uration and will be made available with the machine documentation.
7.1 Machine data overview
BC 1001 HS
(4050.101)
BC 1007 HS
(4050.107)
BC 1008 HS
(4050.108)
BC 2014 HS
(4050.230)
Electrical connection [V, ~, Hz]
400, 3, 50
400, 3, 50
400, 3, 50
400, 3, 50
Rated current (max.) [A]
32
32
32
32
Control voltage (DC) [V]
24
24
24
24
Weight without options [kg]
1,600
2,300
2,700
4,000
Maximum panel dimensions
(W x H x D)
(clamping/machining) [mm]
2,500 x 1,500 x 5 /
2,260 x 1,500 x 5
2,500 x 1,500 x 5 /
2,260 x 1,500 x 5
2,500 x 1,500 x 5 /
2,260 x 1,500 x 5
2,500 x 1,500 x 5 /
2,260 x 1,500 x 5
Maximum feed rate [mm/min]
3,000
3,000
3,000
3,000
Typical feed rate in series oper-
ation (Performance) [mm/min]
900
900
900
900
Max. spindle speed [RPM]
21,000
21,000
21,000
21,000
Max. spindle power [kW]
11
11
11
11
Axis speed:
X axis [mm/min]
60,000
60,000
60,000
60,000
Axis speed:
Y axis [mm/min]
60,000
60,000
60,000
60,000
Axis speed:
Z axis [mm/min]
12,000
20,000
20,000
20,000
Tool magazine size
18
18
20
20
: Machine data
7.1.1 Noise emissions
LpA workplace-related emission values determined in accordance with EN
848-3:
No load: 66.5 dB(A)
Working noise level: 78.8 dB(A)
The measurement uncertainty constant K is 4 dB(A).
The following supplements specified by the CEN-TC142 to achieve an accu-
racy class better than 3 dB have been considered:
The environmental correction factor k3A is ≤ 4 dB
The difference between the external sound pressure level and the sound
pressure level at each measurement point is ≥ 6 dB