GX-3R Pro Operator’s Manual Chapter 3: Operation38
Low Battery Warning The last bar in the battery icon
starts flashing
None
Dead Battery Alarm
Gas readings disappear and FAIL
BATTERY appears at the bottom
of the LCD
Alarm LEDs flash once per
second
Double pulsing tone once
per second
Sensor Failure
FAIL SENSOR appears at the
bottom of the LCD and the failed
sensor(s) are indicated with FAIL
under the gas name.
Alarm LEDs flash once per
second
Double pulsing tone once
per second
LIMITED HC GAS LIST
LIMITED HC GAS LIST
appears on the screen
Alarm LEDs flash once per
second
Double pulsing tone once
per second
Clock Failure
FAIL CLOCK appears at the
bottom of the LCD
Alarm LEDs flash once per
second
Double pulsing tone once
per second
System Failure
FAIL SYSTEM appears at the
bottom of the LCD and an error
code displays in the middle of the
LCD
Alarm LEDs flash once per
second
Double pulsing tone once
per second
Man Down Warning 1
The WARNING 1 TIME defined in
User Mode has passed since the
instrument detected movement.
Alarm LEDs flash once per
second
Single pulsing tone once
per second
Man Down Warning 2
The WARNING 2 TIME defined in
User Mode has passed since the
instrument detected movement.
Alarm LEDs flash twice per
second
Single pulsing tone twice
per second
Alarm Type Visual Indications Other Indications