Loading...
46 Rockwell Automation Publication 2198-RM005A-EN-P - October 2020
Chapter 4 System Architecture
Kinetix 5300 Drive
Hardware and Input Power
Configurations
Typical Kinetix 5300 systems include single-phase and three-phase standalone
configurations.
In this example, a single drive is shown with input power to the standard AC and
24V DC input connectors.
Figure 22 - Typical Kinetix 5300 Standalone Installation
1606-XL
Power Supply
Input
Allen-Bradley
L3L2
L1
24+
DC+ SH
24-
SB+
SB-
S1
SC
S2
MBRK
W
V
U
1
10
1
2
MFB
Single-phase or
Three-phase
Input Power
Line
Disconnect
Device
Circuit
Protection
2097-Rx or 2198-Rxxxx
Shunt Resistor
(optional component)
2198-Cxxxx-ERS Drive
(top view)
AC Input Power
Bonded Cabinet
Ground Bus
Mains AC Input Wired to
Standard Input Connector
1606-XLxxx
24V DC Control, Digital Inputs,
and Motor Brake Power
(customer-supplied)
2198-Cxxxx-ERS Drive
(front view)
24V DC Input Wired to
Standard Input Connector
2198-DB08-F or
2198-DBRxx-F
AC Line Filter
(is required for CE)
Motor
Refer to Table 36
.
Bulletin 2090
Motor Feedback Cables
Bulletin 2090
Motor Power Cables

Other manuals for Rockwell Automation Allen-Bradley Kinetix 5300