9-12 MD60 AC Drive User Manual
Sets the rate of deceleration for speed decreases if A051 or A052 is
set to option 1 (Accel 2 and Decel 2). See figure 9.4.
Maximum Frequency / Decel Time = Decel Rate
Provides the frequency command to the drive when Speed
Reference (P038) is set to 1 (Internal Frequency). When enabled,
this parameter will change the frequency command in “real time”
using the integral keypad keys when in program mode.
A068 Decel Time 2
Range: 0.1 to 600.0 sec
Default: 10.0 sec
See also: P040
Figure 9.4 – Decel Time 2 (A068)
Speed
0
Time
[Maximum Freq]
[Accel Time] [Decel Time]
0
Acceleration
De
c
e
lerat
ion
A069 Internal Frequency
Range: 0.0 to 240 Hz
Default: 0.0 Hz
See also: P038