A-6
SP600 AC Drive User Manual
Analog Input 2,
Differential Current Input
Signal level
Differential Input resistance
Isolation
Initial accuracy (@25°C)
Resolution
Common Mode Rejection Ratio
Input processing period
Terminal block size
Protection
0(4)-20mA
100
±165V
±0.3%
10 bits (0.1%)
70dB up to 500Hz over temp range
5ms
0.05 mm
2
to 1.5 mm
2
(30 AWG to
16 AWG)
ESD protected (6 kV contact
discharge, 8 kV air discharge)
Analog Output
Analog output voltage range
Loading impedance
Accuracy over temperature range
Resolution
Frequency of output waveform
Output processing period
Terminal block size
Protection
0 to +10V
2k minimum
±2.35% maximum
10 bits (0.1%)
160Hz maximum
5ms
0.05 mm
2
to 1.5 mm
2
(30 AWG to
16 AWG)
Short circuit proof, ESD protected
(6 kV contact discharge, 8 kV air
discharge)
Reference Power Supply
Output Voltage
Potentiometer resistance range
Accuracy over temperature range
Terminal block size
Protection
10V
2k to 10k
±2.35% maximum
0.05 mm
2
to 1.5 mm
2
(30 AWG to
16 AWG)
Short circuit proof, ESD protected
(6 kV contact discharge, 8 kV air
discharge)
24V Power Supply
Output Voltage
Output Current
Isolation
Terminal block size
Protection
24V to 28V
150mA maximum
±25V
0.05 mm
2
to 1.5 mm
2
(30 AWG to
16 AWG)
Short circuit proof, ESD protected
(6 kV contact discharge, 8 kV air
discharge)
Table A.6 – Control Inputs, Outputs, and Power Supplies (Continued)