switches ON / OFF; if the zone LED is ON means the appropriate attribute is enabled and if
the zone LED is OFF means the attribute is disabled.
ATTRIBUTES
1
set
The alarm triggered by a zone with this attribute set as „audible” type will
occur with siren activating for a time lapse set in section [39].
The alarm triggered by a zone with this attribute set as „silent” type will
occur without siren activating.
This attribute is referring to the siren-activating mode – “steady” or
“pulsing” and for a same zone the set value of this attribute does
mater only if the previous attribute was set as „audible” type.
The alarm triggered by a zone with this attribute set as „steady siren” type
will activate the siren in a continuously mode for a time lapse set in section
[39].
The alarm triggered by a zone with this attribute set as „pulsing siren” type
will activate the siren in a pulsing mode (3 seconds ON alternating with 1
second OFF) for the same time lapse set in section [39].
Allows
manually
bypassing
*
doesn’t allow
manually
bypassing
When a zone allows manually bypassing it will allow to be bypassed by one of
the commands: [*][3][User code] or [BYPASS][User Code].
allows auto
shutdown
from
swinger
doesn’t
allow auto
shutdown
from
swinger
*
During the same armed period (or during the same disarming period for 24h
zones) the control panel will automatically bypass (“from swinger”) any zone
which allows auto-shutdown and after the zone initiate a number of
consecutive alarms equal with “swinger shutdown counter”. After that the
zone will no longer generate an alarm. After the control panel has bypassed a
zone “from swinger”, it will report an event code to the central station, if it is
programmed within [55] and [66] sections. This feature is a function of the
zone restore option which is displayable on zone 5 LED within [20] section.
During the same armed period (or during the same disarming period for 24h
zones) the zone will be bypassed “from swinger” only:
After the siren has cut-off consecutive times, for a number equal with
“swinger shutdown counter”, if zone restore event is set to occur upon
bell cut-off;
After the zone has violated and closed back for a number equal with “swinger
shutdown counter”, if zone restore event is set to occur upon zone
closure.
Thus, during the same armed period (or during the same disarming period for
24h zones), a zone which allows “auto shutdown” will trigger:
A maximum alarm number equal with “swinger shutdown counter”
established in [29] section, if zone restore event is set to occur upon
zone closure;
A maximum number of siren triggering equal with “swinger shutdown
counter” established in [29] section, if zone restore event is set to occur
upon bell cut-off; please note that in this case, if the “report only first zone
alarm” option is disabled, too, such a zone may record more alarms than
„swinger shutdown counter”.
doesn’t
allow
forced
arming
*
When a zone allows forced arming, it will allow system/partition
arming although the zone is being violated at the very moment of
arming (i.e. the system can be armed even though the PIR detector
nearby the keypad detects movement when arming).
When a zone has the „chime” attribute enabled, while the system is
disarmed and the „chime” feature was activated previously by the
command [*][6], any „opening” of the zone will make the keypad
buzzer sounds 6 warning beeps.
When a zone has the „stay” attribute enabled, it is an interior zone and will be
automatically bypassed by the system during stay arming” or “instant stay
arming” modes.
When a zone hasn’t the „stay” attribute enabled, it is an perimeter zone