34
After the ATTRIBUTES
1
set for the selected zone was established to the required values,
press [#] key to confirm.
After [#] key was pressed, the keypad buzzer will sound 3 confirmation beeps and the
panel will pass to the next step, displaying the ATTRIBUTES
2
set on 1 to 5 Zone LEDs.
While the system is within ATTRIBUTES
2
displaying submenu, the keypad LEDs’ status will be as
follows:
ARMED A LED
ON
ARMED B LED
OFF
SYSTEM LED
Blinking
READY A LED
Blinking
READY B LED
OFF
1 to 5 Zone LEDs
ON / OFF, according to the ATTRIBUTES
2
set of the selected zone
Pressing [#] key, ATTRIBUTES
2
set can be maintained as it was previously established.
1.3 Second set of zone attributes are display-able on 1 to 5 Zone LEDs, according to the table
below. In order to establish the ATTRIBUTES
2
set, you should press the numeric keys
which correspond to the Zone LEDs. After each key pressing the appropriate zone LED
switches ON / OFF; if the zone LED is ON means the appropriate attribute is enabled and if
the zone LED is OFF means the attribute is disabled.
ATTRIBUTES
2
set
After the ATTRIBUTES
2
set for the selected zone was established to the required values,
press [#] key to confirm.
After [#] key was pressed, the keypad buzzer will sound 6 confirmation beeps and the
panel will go back within „main programming menu”.
To exit the main programming menu, press [#] key again.
ATTRIBUTES
2
set:
Zone LEDs
ON
OFF
Remarks:
Zone 1 LED
Intellizone
*
Zone
responds as
normal
When a zone has the „intellizone” attribute enabled, any first
„violation” of the zone will start the “timer for intellizones” and it will
only cause an alarm when:
a) The zone remains violated for a longer time than “time window
for intellizones”.
b) The zone is violated twice within “time window for intellizones”.
c) If any active zone is violated within “time window for
intellizones”.
Zone 2 LED
2EOL with
tamper
recognition
*
EOL no
tamper
recognition
When a zone has the “tamper recognition” attribute enabled, short
circuit or open zone loop are treated as zone tamper condition.
Sensors have to be connected using the double end-of-line resistor
diagram (see page ).
In case option 5 in programming section [21] is enabled, no
matter if the system is armed or disarmed, zone tamper condition
will activate the siren, and the panel will report and save in the event
log the tamper alarm condition. If this option is disabled, and the
system is disarmed, no alarm will be generated in case of zone
tamper condition.
Zone 3 LED
Enable ATZ
*
Disable ATZ
Advanced technology zone (ATZ) connections allow you to install
two detection devices per input terminal, therefore, doubling zone
capacity of the control panel. Advanced technology zoning is a
software-oriented feature, there is no need for extra modules, simply
install the devices as shown in the sections of zone connections and
the control panel will recognize the installed devices as shown there.
The extra zones function exactly like any other zone displaying zone
status on the keypad and sending separate alarm codes for each zone.
Note: By default this feature is disabled for all 1 to 5 hardware zones.
Zone 4 LED
enabled
*
disabled
Belong to 1
-st
partition
Zone 5 LED
enabled
disabled
*
Belong to 2
-nd
partition
Notes:
1. attributes 2 and 3 from the above set, are valid only for low zones (from 1 to 5/8), high zones ( from 6/9 to