b) Dimensions:Connection M14x1.5 metric
Fig. 3 06398
Part Function
1 Fuel pump assy.
Housing: stainless steel
Nominal voltage: 12 V
Capacity: approx. 120 l/h (31.7 US gal/h)
Pressure: min. 4.5 bar (65.3 psi) (absolute pressure)
Absorption
capacity:
up to -400 mbar (-5.8 psi) compared to ambient (depending
on the vapor pressure of the fuel used)
Check valves: a) opening pressure max. 70 mbar (1.02 psi)
b) resistance max. 70 mbar at 75 l/h (19.8 US gal/h)
c) pressure safe up to 20 bar (290 psi)
157mm
73mm
241.8 mm (9.52 in.)
1
213.5mm (8.41in.)
14.5mm
M14x1.5
(6.18 in.)
(2.87 in.)
(0.57 in.)