37
English
- Cold temperature
It allows to assign a service temperature of the
refrigerating compartment between +8°C and +15°C.
- Compressor
It allows to desactivate or activate the compressor.
- Tank
It allows sensor level (optional) reading inside the
discharge fluid tank.
- Coffee/beverage pulse counter
The mechanical pulse counter (optional), enables
choosing whether to count the coffee or the beverages
dispensed.
- Stand-by Text
It allows to enter the text which appears on the display
when the vending machine is in normal operating
mode.
- Dispensing Text
It allows to enter the text, on display, when the vending
machine is dispensing a product.
- Out of Service Text
It allows to enter the text, on the display, when the
vending machine stops for trouble
- Deca preselection
It allows to enable the 7 key (Fig. 59) for the
preselection of decaffeinated coffee. This preselection
allows the user to obtain beverages with the coffee
beans replaced by instant 4 (usually instant
decaffeinated coffee).
- Instant Cycle
It enables the so-called “instant cycle” mode for soluble
4 brewing.
Such brewing mode differs from the usual brewing
cycle of instant beverages as the powder is dispensed
before the water and not simultaneously.
The instant cycle is used for beverages brewing when
all the following conditions are fulfilled:
- “preselection deca” option set on YES;
- “instant cycle” option set on YES;
- The selected soluble is number 4;
- The required soluble quantity is less than 21 (safety
threshold to prevent the mixing bowl from clogging).
The menu can be viewed only if the “COMPLETE
MENUS” option is set on YES.
- Multiple beverage
It allows to set beverage multiple dispensing.
It allows to select which beverages will be enabled for
multiple dispensing and the number of dispensing.
The upper line will remain unchanged for all the
following operations, while the lower one will show
the number of consecutive beverages. It is possible to
set a value between 2 and 8.
8.2.3 Description of messages in
the programming menu
SYSTEM MANAGEMENT
The entries of the SYSTEM MANAGEMENT ARE:
- VM Code
It allows to assign an identification code for the vending
machine.
- Stops
It allows you to set the maximum amount of soluble
powder, water, drink or coffee. Once reached the
maximum amount, the vending machine stops the
dispensing of relevant beverages.
The first digit on the right (“00000”) refers to the
quantity of the product dispensed from the last ‘RESET’
(partial counters).
The left hand digit, preceded by “LIM”, shows the
maximum dispensable quantity (changeable value).
Example:
- Stop coffee
It allows to set the maximum number of coffee cups to
be dispensed before the stop
- Stop beverage
It allows to set the maximum number of individual
beverages to be dispensed before the stop
- Stop soluble
It allows to set the maximum quantity of powder for
each soluble product to be dispensed before the stop
- Stop water
It allows to set the quantity of water to be dispensed
before the stop. Once reached the set quantity,
beverage dispensing is stopped.
- Reset
It allows to reset all partial counters of product quantity
stopping function.
- Minimum temperature
It allows to set the temperature that the vending
machine keeps for a few minutes after a beverage has
been dispensed. Set value is expressed in centigrade.
- Maximum temperature
It allows to assign the temperature to which the vending
machine is brought after a certain time from the last
dispensing, so that the natural lowering of the
temperature of the hydraulic circuits can be
compensated. Set value is expressed in centigrade.
BEVERAGE D
00000 LIM. 000444