4.Troubleshooting
4.5.3.6.PrintReports
•Information>PrintReports
Thismenudisplaysreportswhichthatcanbeprintedfromthesystem.Thefollowingreportswillbeavailabletoprint.
-SuppliesInformation
-FaxProtocolDumpList
-AutoColorRegistrationResult
-Maintenance
-JobDuty
-TRCControlHistory
-OPCACRReport
-UsageCounterReport
-ErrorInformationReport
-DiagnosticsPageReport
AutoColorRegistrationResult
•Information>PrintReports>AutoColorRegistrationResult
Thisreportlistslast10AutoColorRegistrationresults.
Ifthereiscolorregistrationproblem,andexecutionofAutoColorRegistrationdoesnotsolvetheproblem,service
engineerscanprintoutthisreportandcheck“SucceededorFailedforACR”eld.
ResultMeaning
0Success
100SensorLEDcalibrationfailure
200Patternstoragefailureinregister
301Outofnormalrangeinrearpatternwidth
302Outofnormalrangeinfrontpatternwidth
304Outofnormalrangeincenterpatternwidth
308Numberofsensedpatternislagerthannormalnumber(checkITBscratch)
316Numberofsensedpatternissmallerthannormalnumber
e.g.)323Multipleerrors.Forexample301,302,304,316erroroccuratthesametime.Inthatcase,the
sumoflasttwodigitappearsasresult
480Correctedvalueexceedsthelimitofcorrection
TRCControlHistory
•Information>PrintReports>TRCControlHistory
NOTE
TRCmeans“ToneReproductionCurve”.
ThisreportshowshistoryofexecutionofTRCcontrol.TRCcontrolpreservescolorconsistencyagainstchangesin
suppliesresultingfromlong-timeuseandenvironmentalchange.ThepurposeofthehistoryreportistocheckifTRC
controlworksnormally.
Copyright©1995-2013SAMSUNG.Allrightsreserved.4-40