4.Troubleshooting
4.6.1.Ax-xxxxtypeerrorcode
►ErrorCode
A1–1211
A1–1212
A1–1213
►Errormessage
MotorFailure:#A1-1211.Turnoffthenon.Callforserviceiftheproblempersists.
MotorFailure:#A1-1212.Turnoffthenon.Callforserviceiftheproblempersists.
MotorFailure:#A1-1213.Turnoffthenon.Callforserviceiftheproblempersists.
►Symptom
Fusermotoroperationisabnormal.
►Troubleshootingmethod
•A1–1211:Fusermotorisstoppedbutmachinerecognizesitasoperational.
•A1–1212:Fusermotorisnotoperatedforprint-job.
•A1–1213:Fusermotorisoperatingbutmachinerecognizesstatusas"Stopped".
1)Turnthemachineoff.Checkifthereareanyforeignsubstancesorpaperaroundfuserunit.
2)Checkifthefuserunitisdamaged.Ifyes,replacethefuserunit.
3)Removetherearcoverafterremoving7screws.
4)CheckiftheFusermotorconnectorsareconnectedcorrectly.
5)IftheconnectionisOK,turnthemachineon.EnterSVCmode.Selectfusermotortest.
(Diagnostics>EngineDiagnostics>EngineT estRoutines>109–0030)
Copyright©1995-2013SAMSUNG.Allrightsreserved.4-84