EasyManua.ls Logo

Samsung CLX-8640 series - Error Code S5-3111; UI System Failure #S5-3111:Turn off then on

Samsung CLX-8640 series
441 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.Troubleshooting
ErrorCode
S5–3111
Errormessage
UISystemFailure#S5-3111:Turnoffthenon.
Symptom
CommunicationerrorbetweenmainboardandOPEboardhasoccurred.
Troubleshootingmethod
1)Removetherearcover.
(Referto3.3.2RearCover.
)
2)CheckiftheOPEcableisconnectedtothemainboardcorrectly.
3)RemoveanddisassembletheOPEunit.
(Referto3.3.20OPEunit.
)
4)CheckiftheOPEcableisconnectedtotheOPEboardcorrectly.
5)IftheconnectionisOK,replacethemainboard(JC92–02516A).
Copyright©1995-2013SAMSUNG.Allrightsreserved.4-230

Table of Contents

Related product manuals