4.Troubleshooting
►ErrorCode
A1–1611
A1–1612
A1–1613
►Errormessage
MotorFailure:#A1-1611.Turnoffthenon.Callforserviceiftheproblempersists.
MotorFailure:#A1-1612.Turnoffthenon.Callforserviceiftheproblempersists.
MotorFailure:#A1-1613.Turnoffthenon.Callforserviceiftheproblempersists.
►Symptom
ITBmotoroperationisabnormal.
►Troubleshootingmethod
•A1–1611:ITBmotorisstoppedbutmachinerecognizesitasoperational.
•A1–1612:ITBmotorisnotoperatedforprint-job.
•A1–1613:ITBmotorisoperatingbutmachinerecognizesstatusas"Stopped".
1)Turnthemachineoff.CheckifthereareanyforeignsubstancesorpaperaroundITBUnit.
2)RemoveandreinstalltheITBunit.
(Referto3.2.3ITBUnit.
)
3)Removetherearcoverafterremoving7screws.
4)CheckiftheITBmotorconnectorsareconnectedcorrectly.
5)IftheconnectionisOK,turnthemachineon.EnterSVCmode.SelectITBmotortestwhileremovingtheITBunit.
(Diagnostics>EngineDiagnostics>EngineT estRoutines>100–0450)
Checkthemotoroperation.
a)Ifthemotorisnotoperational,
Copyright©1995-2013SAMSUNG.Allrightsreserved.4-88