4.Troubleshooting
ErrorCode
A3–3310
A3–3311
A3–3312
A3–3410
A3–3411
A3–3412
Errormessage
SensorFailure:#A3-3310.Turnoffthenon.Callforserviceiftheproblempersists
ActuatorFanFailure#A3-3311:Turnoffthenon.
ActuatorFanFailure#A3-3312:Turnoffthenon.
ActuatorFanFailure#A3-3410:Turnoffthenon.
ActuatorFanFailure#A3-3411:Turnoffthenon.
ActuatorFanFailure#A3-3412:Turnoffthenon.
Symptom
Outertemperature/humiditysensorisdefective.
Troubleshootingmethod
A3–3310/A3–3311/A3–3312:Temperaturefunctionisabnormal.
A3–3410/A3–3411/A3–3412:Humidityfunctionisabnormal.
1)EnterSVCmode.Executesensortesttocheckthesensoroperation.
(Diagnostics>EngineDiagnostics>EngineTestRoutines)
109-0013:OuterTemperature
109-0014:HumidityTemperature
2)RemovetheCover-LeftTop[A].Remove8screws.Andremovetheleftcover.
3)Checkthetempsensorharnessconnection.
4)Disconnecttheharness.Measuretheresistancevalueoftheconnectoratbothends.
Ifthevalueisnotin47.5KΩ~52.5KΩ(@25),replacethesensor(JC93-00486A).
Copyright©1995-2013SAMSUNG.Allrightsreserved.4-112