4.Troubleshooting
ErrorCode
S2–331C
Errormessage
Calibrating...PleaseWait
Symptom
PrintingJobisstoppedbecauseofhightemperatureinsidemachine.
Troubleshootingmethod
1)Openthesidecover.Coolthemachine.Andclosethesidecover.
2)Iftheproblempersists,enterSVCmode.Executethetemperaturesensortest.
(Diagnostics>EngineDiagnostics>EngineTestRoutines>109-0013OuterT emperature)
3)Checkthetemperaturesensorconnection.IftheconnectionisOK,measuretheresistorvalueofthesensor.
4)Ifthevalueisnotin47.5KΩ~52.5KΩ(@25),replacethesensor(JC32–00015A)
5)IfthetemperaturesensorisOK,removetherearcover.
(Referto3.3.2RearCover.)
6)Replacethemainboard(JC92–02516A).
7)Assembletherearcover.Turnthemachineon.