EasyManua.ls Logo

SANY SRT45 - Page 123

SANY SRT45
286 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SRT45 Off-Highway Truck
3-37
Safety, Operation and Maintenance Manual
56
55 Range verication ratio test, 5th Yes DNS
66 Range verication ratio test, 6th On DNS
77 Range verication ratio test, 7th or R1 Yes DNS
88 Range verication ratio test, 8th or R2 Yes DNS
65 00 Engine rating too high Yes DNS, Lock-in-neutral
66 00 Serial communications interface fault No Use default throttle values
69
27 ECU, inoperative A, B, F, G, I, K solenoid Yes DNS, SOL OFF
28 ECU, inoperative H/J solenoid Yes DNS, SOL OFF
29 ECU, inoperative C, D, E solenoid Yes DNS, SOL OFF
33
ECU, Computer Operating Properly (COP)
fault
Yes
Reset ECU, shutdown ECU on 2nd
occurrence (power loss; hydraulic
de f a ults). May cause c a teye
display or all segments blank display
34 ECU, EEPROM, fault Yes DNS, SOL OFF
35 ECU, EEPROM, fault Yes Reset ECU
39 Communication chip addressing error Yes Use defaults for J1939 data
42 SPI output failure No
GPO 18 and reverse warning
inoperable
43 SPI input failure Yes DNS, lock-in-range
Controls and Operating
Courtesy of Machine.Market

Table of Contents