EasyManua.ls Logo

Sanyo Denki PY2A030 - Page 92

Sanyo Denki PY2A030
138 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PY Manual Copyright © 2006 SANYO DENKI AMERICA, Inc.
91
Electronic Gear Ratio EGER
Remote Operator Mode:
1
Page:
2
Default Value:
4/1
Function:
CMD
Setting Range:
1/32767 to 32767
Description:
• Electronic gear ratio is applied to incoming position commands.
F
in
= Frequency into the amplifier
F
out
= Frequency out of the gear function
EGER = N / D N (1 to 32767)
D (1 to 32767)
F
out
= F
in
x (N / D)
1 / 32767 ≤ N / D ≤ 32767
Note:
•
Since the electronic gear ratio is for changing the magnification ratio of the command pulses, changing this
setting does not change the resolution of the position feedback.
• The encoder in use determines the minimum positioning resolution.
Position Command, Pulse Multiplier PMUL
Remote Operator Mode:
1
Page:
3
Default Value:
1
Function:
CMD
Setting Range:
1 to 63
Description:
• A multiplier for the position command pulse can be selected from 1 to 63.
•
This multiplier is used when the PMUL input terminal is selected by the Func3 parameter.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com