PY Manual Copyright © 2006 SANYO DENKI AMERICA, Inc.
91
Electronic Gear Ratio EGER
Remote Operator Mode:
1
Page:
2
Default Value:
4/1
Function:
CMD
Setting Range:
1/32767 to 32767
Description:
• Electronic gear ratio is applied to incoming position commands.
F
in
= Frequency into the amplifier
F
out
= Frequency out of the gear function
EGER = N / D N (1 to 32767)
D (1 to 32767)
F
out
= F
in
x (N / D)
1 / 32767 ≤ N / D ≤ 32767
Note:
•
Since the electronic gear ratio is for changing the magnification ratio of the command pulses, changing this
setting does not change the resolution of the position feedback.
• The encoder in use determines the minimum positioning resolution.
Position Command, Pulse Multiplier PMUL
Remote Operator Mode:
1
Page:
3
Default Value:
1
Function:
CMD
Setting Range:
1 to 63
Description:
• A multiplier for the position command pulse can be selected from 1 to 63.
•
This multiplier is used when the PMUL input terminal is selected by the Func3 parameter.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com