Output Pulse Divide Ratio ENCR
Remote Operator Mode:
1
Page:
4
Default Value:
1/1
Function:
Monitor
Setting Range:
1 to 1/8192
Description:
• Defines the ratio of encoder pulses (CN2) to control feedback pulses.
F
in
Frequency in from the motor encoder
F
out
Frequency out to a position controller
α
= 1 to 64 or 8192
ENCR
β
α
β
= 1 (when
α
=1 to 64)
= 2 (when
α
=3 to 64)
= 1 to 8191 (when
α
= 8192)
F
out
F
in
β
α
.
Low Speed LTG
Remote Operator Mode:
1
Page:
5
Default Value:
50 min
-1
Function:
Monitor
Setting Range:
0 to 32767 min
-1
Description:
• Low Speed: When the speed decreases below this set level the “low speed” (LTG) status is turned ON if
enabled.
•
The LTG status can be output to CN1-39 or CN1-40 by setting Function Switch 4.