EasyManua.ls Logo

Sanyo Denki PY2A030 - Page 94

Sanyo Denki PY2A030
138 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PY Manual Copyright © 2006 SANYO DENKI AMERICA, Inc.
93
High Speed
HTG
Remote Operator Mode:
1
Page:
6
Default Value:
1000 min
-1
Function:
Monitor
Setting Range:
0 to 32767 min
-1
Description:
• High speed: When the speed exceeds this set level the “high speed” (HTG) status is turned ON (CN1-39) if
enabled.
•
The LTG status can be output to CN1-39 or CN1-40 by setting Function Switch 4.
•
The following switching (control mode) enables a speed limit to be set in the torque control mode:
Velocity Torque
Position Torque
Speed Matching Width SPE
Remote Operator Mode:
1
Page:
7
Default Value:
50 min
-1
Function:
Setting Range:
0 to 32767 min
-1
Description:
• When the difference between the velocity command and the velocity feedback is smaller than the specified
value, the SPE status is turned on if enabled.
• The LTG status can be output to CN1-39 or CN1-40 by setting Function Switch 4.
Internal Velocity Command Value #1 VCI1
Remote Operator Mode:
1
Page:
8
Default Value:
500 min
-1
Function:
Setting Range:
0 to 32767 min
-1
Description:
• Sets a velocity command value.
•
It is enabled by setting the Func3 parameter bits 3, 2, 1, and 0 to “1010” respectively, and turn the CN1-36 pin
“ON” and CN1-35 pin “OFF”.
•
The drive must be configured for velocity mode operation.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com