-37-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
4 Lower DCTI Frequency LOWERDCTIFREQ 1 0 - 1
5 DCTI Gain DCTIGAIN 4 0 - 15
6 DCTI Frequency DCTIFREQ 0 0 - 3
7 Color Shift Limit COLORSHIFTLMT 3 0 - 3
Group
60
Image
0 Center Contrast 534/534/578/492/492/512 0 - 1023
Composite / S-Video / Component
/ Digital /D-RGB-Video /AnalogRGB
/ RGB-Video / HDCP-PC /HDCP-AV
/SCART / PJ-Net
Setting Value=
(MENU Value - MENU Center Value )
x Alpha / 10 + Center
For moels without FPGA:
Sharpness setting Value=
Center-(Menu Value-MENU Center
Value)xAlpha/10
[Setting Value to PW]
Contrast [Max] 1023 [Min] 0
Brightness [Max] 1023 [Min] 0
Color [Max] 1023 [Min] 0
Tint [Max] 180 [Min] 0
Sharpness [Max] 57 [Min] 0
1 Center Brightness 512/512/512/512/512/512 0 - 1023
2 Center Color 560/560/512/512/560/512 0 - 1023
3 Center Tint 90/90/90/90/90/90 0-180
4
Fixed Sharpness (Up
Scaling)
8/8/8/8/8/8 0 - 37
5
Fixed Sharpness (Down
Scaling)
8/8/8/8/8/8 0 - 37
6
Center Sharpness(Models
without FPGA)
8/8/10/16/10/16/ 0 - 37
7 Center WB Red 512/512/512/512/512/512 0 - 1023
8 Center WB Green 512/512/512/512/512/512 0 - 1023
9 Center WB Blue 512/5/12/512/512/512/512 0 - 1023
10 Center BB Red 512/512/512/512/512/512 0 - 1023
11 Center BB Green 512/512/512/512/512/512 0 - 1023
12 Center BB Blue 512/512/512/512/512/512 0 - 1023
13 Alpha Contrast 60/60/60/60/60/60 0-1000
14 Alpha Brightness 90/90/90/90/90/90 0-1000
15 Alpha Color 140/140/140/140/140/140 0-1000
16 Alpha Tint 10/10/10/10/10/10 0-1000
17 Alpha Sharpness 10/10/10/10/10/10 0-1000
18 Alpha WB Red 40/40/40/40/40/40 0- 1000
19 Alpha WB Green 40/40/40/40/40/40 0- 1000
20 Alpha WB Blue 40/40/40/40/40/40 0-1000
21 Alpha BB Red 20/20/20/20/20/20 0-1000
22 Alpha BB Green 20/20/20/20/20/20 0-1000
23 Alpha BB Blue 20/20/20/20/20/20 0-1000
Group75 : Auto Keystone Setup Value
0 Offset 0 -1056 -1056
1 Offset Switch
0
0 - 1
2 Debug Mode
0
0 - 1
3 Service Calibration
0
0 - 1
4 Lock Count
5
1 - 255
5 Delta vert Result
64
1 - 255
6 Angle 1 Count
1
1 - 10
7 Angle 2 Count
14
1 - 10
8 Blind Sector 1
160
0 - 1024
9 Blind Sector 3
32
0 - 1024
10 Blind sector bias
61
0 - 1024
Group104 : Panel (EP7111) Services
0 FRP_SET 100 0-4095
1 DXOut_R
266
0 - 1023
2 DXOut_G
266
0 - 1023
3 DXOut_B
266
0 -1023
4 H_Change_Pos
26
0 - 256
5 SH_Pos
273
0-4095
6 SH_Pos_R
1
0 - 12
7 SH_Pos_G
1
1 - 12
8 SH_Pos_B 1 0 - 12
9 NGR_Pos 48 0 - 127
10 NGR_Width 51 0 - 255
11 FRP_Pos 27 0 - 255
12 SWAP_InOut 1093 0 - 2047
13 OSD_Pos 2 0 - 3

Table of Contents