-44-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
Group
253
Fan Tem Error Setting (Memorized)
Normal Ceiling
0 Temp A Warning (High)
Temp. A to judge the Temp Error at
High (Room)
46 46 30-100
1 Temp B Warning (High)
Temp. B to judge the Temp Error at
High (Panel)
62 62 30-100
2 Temp C Warning (High)
Temp. C to judge the Temp Error at
High (Lamp)
62 62 30-100
3 Temp B-A Warning (High)
Temp. B-A to judge the Temp Error at
High (Clogging Det.)
100 100 0-100
4 Temp C-A Warning (High)
Temp. C-A to judge the Temp Error at
High (Clogging Det.)
100 100 0-100
5 Temp A Warning (Normal)
Temp. A to judge the Temp Error at
Normal (Room)
46 46 30-100
6 Temp B Warning (Normal)
Temp. B to judge the Temp Error at
Normal (Panel)
62 62 30-100
7 Temp C Warning (Normal)
Temp. C to judge the Temp Error at
Normal (Lamp)
60 60 30-100
8 Temp B-A Warning (Normal)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100 100 0-100
9 Temp C-A Warning (Normal)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100 100 0-100
10 Temp A Warning (Eco)
Temp. A to judge the Temp Error at
Eco (Room)
46 46 30-100
11 Temp B Warning (Eco)
Temp. B to judge the Temp Error at
Eco (Panel)
62 62 30-100
12 Temp C Warning (Eco)
Temp. C to judge the Temp Error at
Eco (Lamp)
60 60 30-100
13 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100 100 0-100
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100 100 0-100
15
Temp A Warning Offset
(Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5 0-100
16
Temp B Warning Offset
(Temp)
15 0-100
17
Temp C Warning Offset
(Temp)
15 0-100
18
Temp B-A Warning Offset
(Temp)
100 0-100
19
Temp C-A Warning Offset
(Temp)
100 0-100
20
Temp A Warning Offset
(Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X min
-
ute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
15 0-40
21
Temp B Warning Offset
(Time)
30 0-40
22
Temp C Warning Offset
(Time)
30 0-40
23
Temp B-A Warning Offset
(Time)
40 0-40
24
Temp C-A Warning Offset
(Time)
40 0-40
Group
254
Fan Control Range Setting (Temp/Voltage
Normal Ceiling
0 High Fan Control Min Temp
Temp Sensor Control Start/End Temp
at High
38 38 20-100
1 High Fan Control Max Temp 42 42 20-100
2 High Fan1 Min
Fan Voltage value at High (Unit 0.1V)
95 95 0-255
3 High Fan1 Max 135 135 0-255
4 High Fan2 Min 85 85 0-255
5 High Fan2 Max 130 130 0-255
6 High Fan3 Min 75 75 0-255
7 High Fan3 Max 77 77 0-255
12 Normal Fan Control Min Temp
Temp Sensor Control Start/End Temp
at High
38 38 20-100
13 High Fan Control Max Temp 42 42 20-100
14 Normal Fan1 Min 80 80 0-255