-45-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
15 Normal Fan1 Max
Fan voltage value at Normal (unit:
0.1V)
125 125 0-255
16 Normal Fan2 Min
75 75 0-255
17 Normal Fan2 Max
120 120 0-255
18 Normal Fan3 Min
70 70 0-255
19 Normal Fan3 Max
70 70 0-255
24 Eco Fan Control Min Temp
Temp Sensor Control Start/End Tem.p
at Eco
36 36 20-100
25 Eco Fan Control Max Temp
42 42 20-100
26 Eco Fan1 Min
Fan voltage value at Eco (unit: 0.1V)
65 65 0-255
27 Eco Fan1 Max
115 115 0-255
28 Eco Fan2 Min
70 70 0-255
29 Eco Fan2 Max
110 110 0-255
30 Eco Fan3 Min
53 53 0-255
31 Eco Fan3 Max
53 53 0-255
Group
255
Fan Start/Cooling Setting
0 Fan1 Initial Volt
Fan Start Voltage (0.1V)
60 0-145
1 Fan2 Initial Volt
60 0-145
2 Fan3 Initial Volt
60 0-145
8 Cooling Time L1
Cooling Time setting at Fan Mode L1
(x 30 sec)
1: 30, 3: 90, 15: 450 sec.
3 1-15
9 Cooling Time L2
Cooling Time setting at Fan Mode L2
(x 30 sec)
1: 30, 3: 90, 15: 450 sec.
4 1-15
10 Temp Error Cooling Time
Cooling Time setting at Temp Erro (x
30 sec)
1:30 , 3:90 , 15:450 sec
3 1-15
11
OnStart Cooling Start Thresh-
old
60 0-100
12 After shutdown cooling Cooling after shutdown (0: No, 1: Yes) 1 0-1
Group
257
Fan Dimmer Setting
0
Dimmer Average Check
Period
Dimmer Average measurement Time
(0:10sec, 1:30sec, 2:60sec,
90sec...10:300sec)
1 0-10
Group
258
Fan IC Temp for Network model
0
Standby Cooling Check
Cycle
Temp A check cycle at Standby 5 0-100
1
Standby Cooling Start
Threshold
Cooling start threshold temp A
46 0-100
2 Standby Cooling Enable Cooling in standby Enable 1 0-1
Group
260
Auto Calibration (Commn) * Auto Calibration
0 Execute Calibration 0 0 - 1
Executes Auto-Calibration when
changing the Value (PC White 100%)
1 Loop Count
Maximum Execution Times (OFFSET-
>GAIN)
8 1 - 30
2 Auto Status
Result of Auto-Calibration (Last
Memory)
0 0 / 1 / 9
0: OK, 1: Adjusting,9: Error *
ReadOnly
3 AutoWait Wait Value for each setting 3 1 - 20
4 CHECK -Tolerance Tolerance of OFFSET 4 1 - 255
5 Time out wait Time out waiting time(sec) 20 1-255
Group
261
Auto Calibration (RGB)
0 OFFSET AREA H START
Black Level Acquiring Area H-Start
Position
975 0 - 1000
1 OFFSET AREA V START
Black Level Acquiring Area V-Start
Position
500 0 - 1000
2 GAIN AREA H START
White Level Acquiring Area H-Start
Position
25 0 - 1000
3 GAIN AREA V START
White Level Acquiring Area V-Start
Position
500 0 - 1000
4 Image AREA H WIDTH Black/White Level Acquiring Area 13 0 - 4095
5 Image AREA V HIGHT
Black/White Level Acquiring Area
Height
9 0 - 4095
6 OFFSET target Target Value of Black Level Adj. 20 0 - 1023

Table of Contents