-46-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
7 OFFSET Tolerance Tolerance of Black Level Adj. 1 1 - 1023
8 GAIN target Target Value of White Level Adj. 980 0 - 1023
9 GAIN Tolerance Tolerance of White Level Adj. 1 1 -1023
10 Image Level Tolerance 8 1-255
Group
262
Auto Calibration (CVBS/SVIDEO)
0 Y Image Area Start X Y Acquiring Area H-Start Position 20 0 - 1000
1 Y Image Area Start Y Y Acquiring Area V-Start Position 200 0 - 1000
6 Image Area H Width Image Level Acquiring Area 8 0 - 4095
7 Image Area V Hight Image Level Acquiring Area Height 9 0 - 4095
8 Y Target Level Target Value of Y Level Adj. 915 0 - 1023
11 Gain Tolerance Tolerance of Level Adj. 1 1 - 255
12 Image Level Tolerance
Tolerance of Acquiring Image Level Adj.
2 1 - 255
Group
264
Auto Calibration (YCbCr)
0 Y-OFFSET AREA H START
Y - Offset Acquiring Area H-Start
Position
925 0 - 1000
1 Y-OFFSET AREA V START
Y - Offset Acquiring Area V-Start
Position
500 0 - 1000
2
CB - OFFSET AREA H
START
CB - Offset Acquiring Area H-Start
Position
925 0 - 1000 If not used: use Y's value
3 CB - OFFSET AREA V START
CB - Offset Acquiring Area V-Start
Position
500 0 - 1000 If not used: use Y's value
4
CR - OFFSET AREA H
START
CR - Offset Acquiring Area H-Start
Position
925 0 - 1000 If not used: use Y's value
5 CR - OFFSET AREA V START
CR - Offset Acquiring Area V-Start
Position
500 0 - 1000 If not used: use Y's value
6 Y - GAIN AREA H START 50 0 - 1000
7 Y - GAIN AREA V START 500 0 - 1000
8 CB - GAIN AREA H START 800 0 - 1000
9 CB - GAIN AREA V START 500 0 - 1000
10 CR - GAIN AREA H START 700 0 - 1000
11 CR - GAIN AREA V START 500 0 - 1000
12 Image AREA H WIDTH YCBCR Level Acquiring Area 13 0 - 4095
13 Image AREA V HIGHT YCBCR Level Acquiring Area Height 9 0 - 4095
14 Y - OFFSET TARTGET 4 0 - 1023
15 CB OFFSET TARGET 512 0 - 1023
16 CR OFFSET TARGET 512 0 - 1023
17 Y - GAIN TARGET 900 0 - 1023
18 CB - GAIN TARGET 985 0 - 1023
19 CR - GAIN TARGET 985 0 - 1023
20 OFFSET Tolerance Tolerance of OFFSET Adj. 1 1 - 255
21 GAIN Tolerance Tolerance of GAIN Adj. 2 1 - 255
22 Image Level Tolerance 8 1 - 255
Group
280
AutoPC Adjsut
0 AutoPCAdjustEnable
Auto-PC Adj Operation Enable if Un-
supported Signal Input
0 0 - 1 0: Enable, 1: Disable
1 Frequency Step Frequency Steps of TotalDot 1 0 - 3
2 Frequency Threshold Total Dot Freqency Threshold 5 0 - 10 0 [] <--- -----> 10[Not matched]
3 Fine Phase Do Phase Adj after Total Dot Adj. 1 0 - 1
0: Executes Fine Phase, 1: Not
Execute
4 BLKDET Black Level Detection Area 1 0 - 7
5 PHASEMSK Phase Detection Filter 0 0 - 3
0: Effective All Bit,
1: Disable Lower 1 bit
2: Disable Lower 2 bit, 3: Disable
Lower 3 bit
Group
290
PanelType * Panel Type Check